Human Cytokine (4-Plex)

Product at a Glance

Name: Q-Plex™ Human Cytokine (4-Plex)

Catalog: #115449HU

Kit Type: Multiplex ELISA

Multiplex Format: Antibody Array

Detection Method: Chemiluminescent

Analytes: IL-6, TNFα, IFNy, IL-10

Product Overview

The Q-Plex Human Cytokine (4-Plex) is a fully quantitative ELISA-based chemiluminescent assay allowing concurrent measurement of four biomarkers or analytes (IL-6, TNFα, IFN-γ, IL-10).

Each kit contains a 96-well plate, with each well featuring the relevant biomarker panel, and all the reagents required to perform testing. Q-Plex plates are built by absorbing four distinct capture antibodies in a defined array to the bottom of each well. Our high-quality reagents help ensure the accuracy of your results.

Using just 50 µl of sample per well, up to 80 samples can be assayed for all four markers in the panel in 2.5 hours. Q-Plex Arrays provide scientists with an easy-to-use and cost-effective means of generating a cytokine profile for each sample.

Kit Content

Each kit contains a 96-well plate, featuring the relevant biomarker panel in each well, and all reagents required to perform testing.

Reagents include:

  • Calibrator
  • Detection mix
  • Substrate
  • Sample diluents
  • Wash buffer
Assay Ranges
UnitsCalibrator RangeLLD Limit
IL-6pg/ml3000 - 4.113.47
TNFαpg/ml4000 - 5.495.20
IFN-γpg/ml8000 - 10.974.95
IL-10pg/ml3000 - 4.114.10

Immunochemical Assays and Nucleic-Acid Detection Techniques for Clinical Diagnosis of Prostate Cancer

  • Authors: Prosper Kanyong, Sean Rawlinson, James Davis
  • J Cancer. 2016: doi.org/10.7150/jca.13821

1′-Acetoxychavicol acetate promotes caspase 3-activated glioblastoma cell death by overcoming enhanced cytokine expression

  • Authors: Musa Williams, Illya Tietzel and Quincy A. Quick
  • Oncology Lett. 2013 June; 5(6): 1968–1972.

Development of Electrochemical Immunosensors towards Point-of-care Cancer Diagnostics: Clinically Relevant Studies

  • Authors: Rawiwan Laocharoensuk
  • Electroanalysis. 2016: doi.org/10.1002/elan.201600248

Derivation of hematopoietic cells from adult mesenchymal stem cells

  • Authors: Reza Izadpanah, Eckhard Alt
  • Google Patents. 2016.
Assay Ranges
UnitsCalibrator RangeLLD Limit
IL-6pg/ml3000 - 4.113.47
TNFαpg/ml4000 - 5.495.20
IFN-γpg/ml8000 - 10.974.95
IL-10pg/ml3000 - 4.114.10

Immunochemical Assays and Nucleic-Acid Detection Techniques for Clinical Diagnosis of Prostate Cancer

  • Authors: Prosper Kanyong, Sean Rawlinson, James Davis
  • J Cancer. 2016: doi.org/10.7150/jca.13821

1′-Acetoxychavicol acetate promotes caspase 3-activated glioblastoma cell death by overcoming enhanced cytokine expression

  • Authors: Musa Williams, Illya Tietzel and Quincy A. Quick
  • Oncology Lett. 2013 June; 5(6): 1968–1972.

Development of Electrochemical Immunosensors towards Point-of-care Cancer Diagnostics: Clinically Relevant Studies

  • Authors: Rawiwan Laocharoensuk
  • Electroanalysis. 2016: doi.org/10.1002/elan.201600248

Derivation of hematopoietic cells from adult mesenchymal stem cells

  • Authors: Reza Izadpanah, Eckhard Alt
  • Google Patents. 2016.